User Manual

Command Reference
Elektronik-Systeme Lauer, MAEN976 95
6.49 LAU_CONFIG_GETADDRESSLIST
(0x011E)
Remote Control Address List
If a Lauer Navigation Monitor is configured as remote controller, this command re-
turns the addresses of monitors which should be controlled remotely. The address list
is returned as a bit field with 16 bits, enabling a total number of 16 monitors to be
controlled remotely. A Lauer Navigation Monitor always addresses the monitors
within its own group, starting with the lowest address. The group bits are added au-
tomatically to the address field, before the command is sent.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
10
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x1E ICHKD
0 1 2 3 4 5 6 7...8 8
0x06 ADR
0x4C 0x41 0x55 0x02 ICHKH Ret ICHKD
Ret
Value: 0...65535
Type: Unsigned short
Length: 2
Description: Bit field containing the address list, where the first byte is
LSB. Each bit corresponds to one monitor address. Bit 0
specifies a monitor at address 0 and bit 15 a monitor at
address 15. If a bit is set (1), the corresponding monitor will
be controlled remotely.