6.40 LAU_CONFIG_GETECDISBACKLIGHT
(0x0115)
ECDIS Default Backlight Level
If ECDIS mode is enabled, the backlight and video controller are configured with
predefined settings. This command returns the backlight level used to setup the back-
light in ECDIS mode.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Read the backlight level of the monitor at address 0.7 (group 0, address 7), which is
used in ECDIS mode:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the backlight level in ECDIS mode is 255 (0xFF):
Note:
The backlight level for ECDIS mode depends on the backlight level value sent with the
“BRT” command. Whenever the monitor receives a new backlight level value, it is au-
tomatically assumed to be used in the ECDIS mode, too. This means, if for example the
backlight level value 200 is sent, then the backlight level is manually changed to 150,
activating the ECDIS mode will reset the backlight level to 200 again.
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x15 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0...255
Type: Byte
Length: 1
Description: Backlight level used in ECDIS mode
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x15 0xE9
0 1 2 3 4 5 6 7 8
0x06 0xE7 0x4C 0x41 0x55 0x01 0x0F 0xFF 0x00