User Manual
Command Reference
72 Elektronik-Systeme Lauer, MAEN976
6.28 LAU_CONFIG_GETDHCPTIMEOUT
(0x0109)
DHCP Timeout
Returns the DHCP timeout value in milliseconds. If the monitor is configured to use
a DHCP server to dynamically get an IP address, this value determines the time, in
which a DHCP server must assign an IP address to the monitor. After the time is
elapsed, the configured static IP address is used.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
10
Example
Query the time, for which the monitor at address 0.7 (group 0, address 7) will wait
to get an IP-address from a DHCP server, before using the static IP-address:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor will wait 10000 (0x2710) ms for a DHCP server to get an IP-address,
before using the static IP-address:
0 1 2 3 4 5 6 7...8 9
0x07 ADR 0x4C 0x41 0x55 0x02 ICHKH 0x01 0x09 ICHKD
0 1 2 3 4 5 6 7...8 9
0x06 ADR 0x4C 0x41 0x55 0x02 ICHKH Ret ICHKD
Ret
Value: 0...65535
Type: Unsigned short
Length: 2
Description: Timeout value in milliseconds, where the first byte is LSB
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x09 0xF5
0 1 2 3 4 5 6 7...8 9
0x06 0x07 0x4C 0x41 0x55 0x02 0x0E 0x10 0x27 0xC8