User Manual

Command Reference
54 Elektronik-Systeme Lauer, MAEN976
Response Message (Acknowledge)
Maximum Lr for this Command
13
Example 1
Set the green channel level of monitor at address 0.7 (group 0, address 7) to 190 (the
hexadecimal value of 190 is 0xBE, which is represented in ASCII as “BE” and split
into two ASCII codes as 0x42 0x45):
Monitor at address 0.7 (group 0, address 7) has acknowledged the new green channel
level 190 (0xBE):
Example 2
Query the current green channel level of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has returned the current green channel
level 190 (0xBE):
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x4D 0x43 0x43 LEN ICHKH 0xB5 Param Ret ICHKD
Ret
Value: “00”: low...“FF”: high
Type: Two-digit ASCII-encoded hexadecimal number
Length: 2
Description: Current value of the green channel
0 1 2 3 4 5 6 7...9 10
0x07 0x07
0x4D 0x43 0x43 0x03 0x1B 0xB5 0x42 0x45 0xC3
0 1 2 3 4 5 6 7...11 12
0x06 0x07
0x4D 0x43 0x43 0x05 0x1A 0xB5 0x42 0x45 0x42 0x45 0x3C
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0xB5 0x3F 0x0B
0 1 2 3 4 5 6 7...10 11
0x06 0x07
0x4D 0x43 0x43 0x04 0x1B 0xB5 0x3F 0x42 0x45 0x84