Example 1
Set the colour temperature of monitor MT223 at address 0.15 (group 0, address 15)
to “5000K” (which is ASCII “3” with ASCII-code 0x33):
Monitor MT223 at address 0.15 (group 0, address 15) has acknowledged the new
colour temperature “5000K” (0x33):
Example 2
Query the colour temperature of monitor MT223 at address 0.15 (group 0, address
15):
Monitor MT223 at address 0.15 (group 0, address 15) has returned the colour tem-
perature “5000K” (which is ASCII “3” with ASCII-code 0x33):
Example 3
Reset the colour temperature of monitor MT226 at address 0.15 (group 0, address
15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the default co-
lour temperature “USER” (which is ASCII “8” with ASCII-code 0x38):
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0xB3 0x33 0x19
0 1 2 3 4 5 6 7...9 10
0x06 0x0F
0x4D 0x43 0x43 0x03 0x14 0xB3 0x33 0x33 0xE6
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0xB3 0x3F 0x0D
0 1 2 3 4 5 6 7...9 10
0x06 0x0F
0x4D 0x43 0x43 0x03 0x14 0xB3 0x33 0x33 0xDA
0 1 2 3 4 5 6 7...8 9
0x07 0x0F 0x4D 0x43 0x43 0x02 0x14 0xB3 0x52 0xFA
0 1 2 3 4 5 6 7...9 10
0x06 0x0F 0x4D 0x43 0x43 0x03 0x14 0xB3 0x52 0x38 0xC2