User Manual
Command Reference
46 Elektronik-Systeme Lauer, MAEN976
Example 3
Reset the PIP window signal source of monitor MT226 at address 0.15 (group 0, ad-
dress 15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the default PIP
signal source “DVI” (which is ASCII “19” with ASCII-codes 0x31 0x39):
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0xA7 0x52 0x06
0 1 2 3 4 5 6 7...10 11
0x06 0x0F
0x4D 0x43 0x43 0x04 0x13 0xA7 0x52 0x31 0x39 0x9C