User Manual

Command Reference
Elektronik-Systeme Lauer, MAEN976 45
Response Message (Acknowledge)
Maximum Lr for this Command
13
Example 1
Set the PIP window signal source of monitor MT226 at address 0.15 (group 0, ad-
dress 15) to “VGA” (which is ASCII “17” with ASCII-codes 0x31 0x37):
Monitor MT226 at address 0.15 (group 0, address 15) has acknowledged the PIP
window signal source “VGA” (0x31 0x37):
Example 2
Query the current PIP window signal source of monitor MT226 at address 0.15
(group 0, address 15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the current PIP
window signal source “VGA” (which is ASCII “19” with ASCII-codes 0x31 0x37):
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x4D 0x43 0x43 LEN ICHKH 0xA7 Param Ret ICHKD
Ret
Value: “02”: VIDEO1
“03”: VIDEO2
“05”: SVIDEO1
“08”: CMPT1
“18”: SD-RGB
“0A”: COMP3
“17”: VGA
“19”: DVI
“1B”: HD-SDI
Type: Two-digit ASCII-encoded hexadecimal number
Length: 2
Description: Current video signal source
0 1 2 3 4 5 6 7...9 10
0x07 0x0F
0x4D 0x43 0x43 0x03 0x13 0xA7 0x31 0x37 0xF0
0 1 2 3 4 5 6 7...11 12
0x06 0x0F
0x4D 0x43 0x43 0x05 0x1A 0xA7 0x31 0x37 0x31 0x37 0x88
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0xA7 0x3F 0x19
0 1 2 3 4 5 6 7...10 11
0x06 0x0F
0x4D 0x43 0x43 0x04 0x13 0xA7 0x3F 0x31 0x37 0xB1