User Manual
Command Reference
42 Elektronik-Systeme Lauer, MAEN976
6.11 MCC_ PIPWINDOWSIZESELECT (0xA6)
PIP (Picture In Picture) Window Size
Selection
Sets or queries the size of the PIP window.
Supported since Firmware Version
MT223 NAV-230G: Not supported
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x07 ADR
0x4D 0x43 0x43 LEN ICHKH 0xA6 Param ICHKD
Param: ABSOLUTE
Value: “00”: PIP off
“01”: Large
“02”: Small
“03”: Side by side
Type: Two-digit ASCII-encoded hexadecimal number
Length: 2
Description: New PIP window size
Param: RESET
Value: “R” or “r” (0x52 or 0x72)
Type: ASCII character
Length: 1
Description: Reset the PIP window size to an internally predefined value
Param: QUERY
Value: “?” (0x3F)
Type: ASCII character
Length: 1
Description: Query the current PIP window size
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR
0x4D 0x43 0x43 LEN ICHKH 0xA6 Param Ret ICHKD
Ret
Value: “00”: PIP off
“01”: Large
“02”: Small
“03”: Side by side
Type: Two-digit ASCII-encoded hexadecimal number
Length: 2
Description: Current PIP window size