User Manual
Command Reference
Elektronik-Systeme Lauer, MAEN976 41
Example 1
Set the gamma value of monitor MT223 at address 0.7 (group 0, address 7) to
“CRT” (which is ASCII “1” with ASCII-codes 0x31):
Monitor MT223 at address 0.7 (group 0, address 7) has acknowledged the new gam-
ma value “CRT” (0x31):
Example 2
Query the current gamma value of monitor MT223 at address 0.7 (group 0, address
7):
Monitor MT223 at address 0.7 (group 0, address 7) has returned the current gamma
value “CRT” (which is ASCII “1” with ASCII-code 0x31)
Example 3
Reset the gamma value of monitor MT223 at address 0.7 (group 0, address 7):
Monitor MT223 at address 0.7 (group 0, address 7) has returned the default gamma
value “Linear” (which is ASCII “0” with ASCII-code 0x30)
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0x9D 0x31 0x31
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4D 0x43 0x43 0x03 0x01C 0x9D 0x31 0x31 0x00
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0x9D 0x31 0x23
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4D 0x43 0x43 0x03 0x1C 0x9D 0x3F 0x31 0xF2
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0x9D 0x52 0x10
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4D 0x43 0x43 0x03 0x1C 0x9D 0x52 0x30 0xE0