Example 3
Query the current main signal source of monitor MT226 at address 0.15 (group 0,
address 15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the current main
signal source “VGA” (which is ASCII “17” with ASCII-codes 0x31 0x37):
Example 4
Reset the main signal source of monitor MT226 at address 0.15 (group 0, address
15):
Monitor MT226 at address 0.15 (group 0, address 15) has returned the default main
signal source “VGA” (which is ASCII “17” with ASCII-codes 0x31 0x37):
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0x98 0x3F 0x28
0 1 2 3 4 5 6 7...10 11
0x06 0x0F
0x4D 0x43 0x43 0x04 0x13 0x98 0x3F 0x31 0x37 0xC0
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0x98 0x52 0x15
0 1 2 3 4 5 6 7...10 11
0x06 0x0F
0x4D 0x43 0x43 0x04 0x13 0x98 0x52 0x31 0x37 0xAD