User Manual

Command Reference
Elektronik-Systeme Lauer, MAEN976 35
Response Message (Acknowledge)
Maximum Lr for this Command
11
Example 1
Set the scaling mode of monitor MT226 at address 0.15 (group 0, address 15) to
“Letterbox” (which is ASCII “1” with ASCII code 0x31):
Monitor MT226 at address 0.15 (group 0, address 15) has acknowledged the new
scaling mode “Letterbox” (0x31):
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x4D 0x43 0x43 LEN ICHKH 0x8C Param Ret ICHKD
MT223 NAV-230G
Ret
Value: “0”: One to one
“1”: Fill all
“2”: Fill aspect ratio
Type: One-digit ASCII-encoded hexadecimal number
Length: 1
Description: Current scaling mode
MT226 NAV-230G
Ret
Value: “0”: Full screen
“1”: Letterbox
“2”: Pillarbox
“3”: Pillarbox expand
“4”: Letterbox expand
“5”: Waterglass
“6”: Panoramic
Type: One-digit ASCII-encoded hexadecimal number
Length: 1
Description: Current scaling mode
0 1 2 3 4 5 6 7...8 9
0x07 0x0F
0x4D 0x43 0x43 0x02 0x14 0x8C 0x31 0x42
0 1 2 3 4 5 6 7...9 10
0x06 0x0F 0x4D 0x43 0x43 0x03 0x14 0x8C 0x31 0x31 0x11