Owner's manual

Command Reference
Beijer Electronics, MAEN975 71
6.35 LAU_CONFIG_GETPOTMODE (0x0113)
POT Mode
Returns the local backlight level control configuration. If the local backlight control
is enabled, the backlight level can be changed using the front panel buttons and by
remote control (serial or Ethernet interface, analog or digital input). If the local back-
light control is disabled, the backlight level cannot be changed using the front panel
buttons. It can be still changed by any remote control option. The configured back-
light level control can be temporarily overridden by the SCOM command “POT”.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Get the local backlight level control configuration of the monitor at address 0.7
(group 0, address 7):
According to the data returned by the monitor at address 10.7 (group 0, address 7),
the local backlight level control is enabled:
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x13 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0x00: Local backlight level control enabled
0x01: Local backlight level control disabled
Type: Byte
Length: 1
Description: Local backlight level control mode
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4C 0x41 0x55 0x02 0x0D 0x01 0x13 0xEB
0 1 2 3 4 5 6 7 8
0x06 0x07 0x4C 0x41 0x55 0x01 0x0F 0x00 0xFF