Owner's manual

Command Reference
Beijer Electronics, MAEN975 67
6.32 LAU_CONFIG_GETCOMSERMODE
(0x0110)
SCOM Serial Interface Mode
Returns the software configured serial interface mode. The value returned by this
functions is used, if the monitor is configured to override the DIL (DIP) switch
settings. The serial interface mode indicates the physical type of the serial interface
used for the SCOM communication. Available modes are RS232 and RS485. RS232
allows a point-to-point communication, i.e. computer and monitor or monitor and
monitor. With RS485, many monitors can be attached to the same physical line and
can be controlled by one or more computers, allowing a kind of networking. Limi-
tation is given only by the physical characteristics of the RS485 bus.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x10 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0x00: The serial interface is configured as RS232
0x01: The serial interface is configured as RS485
Type: Byte
Length: 1
Description: Software configured serial interface mode used for SCOM
communication