Owner's manual

Command Reference
Beijer Electronics, MAEN975 63
6.28 LAU_CONFIG_GETMANUFACTURER
(0x010C)
Manufacturer
Requests the manufacturer ID from the monitor. The manufacturer ID is a short,
max. 7 character ASCII-string containing the manufacturer specific code. For mon-
itors manufactured by Beijer Electronics, the returned code is always “LAU”. Actu-
ally, this command returns the same value as the standard SCOM command
“MAN”.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
15
Example
Query the manufacturer ID of the monitor at address 0.7 (group 0, address 7):
The monitor at address 0.7 (group 0, address 7) has returned “0x4C 0x41 0x55”,
which represents the ASCII-string “LAU”, indicating that the monitor is manufac-
tured by Beijer Electronics:
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x0C ICHKD
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR
0x4C 0x41 0x55 LEN ICHKH Ret ICHKD
Ret
Value: ASCII characters
Type: String
Length: 0...7
Description: ASCII-string containing the manufacturer ID
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4C 0x41 0x55 0x02 0x0D 0x01 0x0C 0xF2
0 1 2 3 4 5 6 7...9 10
0x06 0x07
0x4C 0x41 0x55 0x03 0x0D 0x4C 0x41 0x55 0x1D