Owner's manual
Command Reference
Beijer Electronics, MAEN975 53
6.18 LAU_CONFIG_GETHOSTNAME (0x0102)
Host Name
Returns the network name of the monitor. The network must support the WINS
protocol for name resolution, to access the monitor using its name.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
16
Example
Get the network host name of monitor at address 0.7 (group 0, address 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor’s host name is “LAU0001”:
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x02 ICHKD
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR
0x4C 0x41 0x55 LEN ICHKH Ret ICHKD
Ret
Value: ASCII characters
Type: String
Length: 1...8
Description: ASCII-string containing the host name
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x02 0xFC
0 1 2 3 4 5 6 7...13 14
0x06 0x07
0x4C 0x41 0x55 0x07 0x09 0x4C 0x41 0x55 0x30 0x30 0x30 0x31 0x5C