Owner's manual

Command Reference
46 Beijer Electronics, MAEN975
Example 3
Decrement the current blue channel level of monitor at address 0.7 (group 0, address
7):
Monitor at address 0.7 (group 0, address 7) has returned the new blue channel level
189 (0xBD):
Example 4
Reset the blue channel level of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has returned the default blue channel lev-
el 128 (0x80):
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4D 0x43 0x43 0x02 0x1C 0xB6 0x2D 0x1F
0 1 2 3 4 5 6 7...10 11
0x06 0x07
0x4D 0x43 0x43 0x04 0x1B 0xB6 0x2D 0x42 0x44 0x96
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4D 0x43 0x43 0x02 0x1C 0xB6 0x72 0xD7
0 1 2 3 4 5 6 7...10 11
0x06 0x07 0x4D 0x43 0x43 0x04 0x1B 0xB6 0x72 0x38 0x30 0x6F