bc-12er 12 channel receiver bc-20 plus 20 channel receiver
+/- 125% Connected device will set to the programmed
position
0 Neutral signal will be provided (1.5ms)
Ausschaltwert Defines the position of the connected device during park
[switch off value] mode (choosing and connecting to new model with transmitter)
halten Current position will be held
[hold]
kein Sig. No servo signal send to the connected device
[no signal]
+/- 125% Connected device will be set to the programmed
position
0 Neutral signal will be provided (1.5ms)
Funkabrisswert Defines the position of the connected device when the signal is
[fail safe] lost or the transmitter is switched off
halten Current position will be held
[hold]
kein Sig. No servo signal send to the connected device
[no signal]
+/- 125% Connected device will be set to the programmed
position
0 Neutral signal will be provided (1.5ms)
Wie begrenzen ohne Feature disabled
[limtation of signal] [without]
Endschalter Pos +-100 This output will be set to neutral from
[limit switch] this positive value and higher
Neg +-100 This output will be set to neutral from
this negative value and below
50%Endsch +100 Just -100%..0% can be used
-100 Just 0%..100% can be used
0 -100%..+100& can be used
(to be used for limit switches)
+100% +100 -100%..+100% can be used
0 -100%..0% can be used
-50 -100%..-50% can be used
-100% +50 +50%..+100% can be used
0 0..+100% can be used
-100 -100%..+100% can be used