Technical data

brixlelektronik
...we got the solution
bc-12er 12 channel receiver bc-20 plus 20 channel receiver
Operation status of the module
bc-12er
Upon delivery output 1 on the module is configured as a status output. A connected
LED will show the different states of the module.
Permanent on = Connected to the transmitter
slow flash(long on/long off)= Module in programming mode
flash (long off/flash) = Module in park mode
quick flash (short off/flash) = Module in fail safe mode – connection lost
very long off/flash = Module powered up – check ok
Using the infrared connection this output will show the status of the ir-connection.
The status can be reprogrammed on any other output and can also be eliminated.
The settings described below can only be performed if any of the outputs is defined
as a status out put.
bc-20 plus
The bc-20 plus is equipped with a green LED onboard. This LED will show the
status of the module.The flash codes are similar to the bc-12er. The settings
described below can be changed on output 33 wich is permanently assigned to
the built in status LED.
Funktion: Status [Feature: Status]
With this feature you can assign a number to the the bc-12er module. This is
required for cable linked modules for remote programming. This module number
must be unique in one model and is only required for programming. In normal
operation all linked modules will get the information sent out by the transmitter.
If you are operating more than one module this number must be assigned to each
individual module. 0 should not be used as this is a general adress to access
modules with unknown identifier. If you got a module with an unknown identifier the
tranmitter can access this module with the adress 0. In this case connect just one
module with an unnown identifier to an antenna and connect to the transmitter. With
0 this module can be accessed and reprogrammed.
To link bc-12er modules in one model the antenna must be connected parallel with
a 4 wire cable to all modules. A y-connection cable (bc-ypsylon) is available to
connect 2 modules.
Please note that the telemetric option will just work with module 1 !
This feature should only be used with tranmitters with a software version 1.500 and
23.06.14 Vxx417