Remarks:
Antenna
Never connect or disconnect the antenna while the receiver is powered up! This
might destroy the modules. The colour coded cable of the antenna is facing away
from the receiver!
Mounting
Depending on the model and the available space for mounting the module can
installed with or without the attached plastic cover. For this purpose we deliver both
parts seperately. If the module is installed without the plastic cover ensure proper
isolation. The module can be fixed in the plastic cover using 2 drops of hot glue.
Module adress
If you are running linked module in a model, ensure a proper assignment of module
numbers. Moule number 1 must be be assigned. This is the only module that can be
used for telemetry purposes. Adress 0 must not be assigned to any of the modules!
Running a single module adress 0 can be used. Moules will be delivered with this
adress.
Modules connected via infrared can not be programmed using this connection. To
program a module which is intended to be used via infrared an antenna must be
connected directly and the module adress must be 0. Once programming is done
the antenna can be removed an the infrad red connection can be used.
If you are using Servonaut or SGS equipment with multiple input lines (motor control
and steering or additional functions) make sure that all inputs of these modules will
be connected to either outputs 1-7, 8-14 or 15-20. Output signals will be send to
these groups of outputs simultaniously and can cause problems when these groups
will be mixed.
Power supply
The bc-20 plus is equipped with a powerful internal BEC system. Do not add
additional BEC systems to this module! The module should not be supplied
from the output side with +5V at any time. Disregard will cause serious
damage to the module!
Power supply for the bc-20 plus is intended to be used with 2s..3s LiPo cellls
(6V..12.6V) or 6..10 NiMh cells (6.0V..14V). Do not use 4s LiFePo4 cells as they
might damage the module due to their higher voltage level!
Linking bc-20 plus modules
If you would like to link multiple bc-20 plus modules please refer to
service@brixlelektronik.de for further information.