Technical data
brixlelektronik
...we got the solution
–bc-12er 12 channel receiver bc-20 plus 20 channel receiver
[Current 10] the measurement range of 0..10A(15A peak). Sensor up
to 50A upon request.
Temp.99 Temperature measurement using the bc-MM-Temp with
the measurment range of 0..99.9°C
Temp.120 Temperature measurement using the bc-MM-Temp with
the measurment range of -20..120°C
Poti Measurement of a potentiometer connected to a
[Pot] bc-MM-Poti with the range of -125% to +125%
Druck PY Measurement of pressure using the bc-MM-Dr-Pisello
[Pressure PY] sensor with the range of 0.0..34.0bar
Druck PMT Measurement of pressure using the bc-MM-Dr-PMT
[Pressure PMT] sensor with the range of 0.0..33.0bar
Druck Damitz Measurement of pressure using the bc-MM-Dr-Damitz
[Pressure Damitz] sensor with the range of 0.0..35.0bar. This sensor is
designed to be mounted directly on the Damitz valves.
Druck bel Measurement of pressure using the
[Pressure brixl] bc-MM-DR-brixlelektronik sensor with the range of
0.0..35 bar. This sensor is equipped with a 3mm thread
for universal connection
Please note that the range of the displayed pressure migh differ from the ranges
printed on the sensors. This is system related and ha no effect on the display
values.
Min.Alarm 0.0-100.0 If the measured value falls below this value an alarm is t
riggered
Max.Alarm 0.0-100.0 If the measured value exceeds this value an alarm is
triggered
An alarm will trigger the red LED on the transmitter and they start flashig. The tactile
alarm (vibration) is triggered 2 times upon the start of an alarm and 1 time when
the alarm condition will dissappear.
Funktion: IR-Sender [Feature: IR-Transmitter]
This fature can be enabled on output 12 on the bc-12er. The bc-20er is equipped
with a dedicated output for an ir led with integrated resistor. All input devices will be
transmitted except y and z.
Funktion: IR-Empfänger [Feature: IR Receiver]
This feature can be enabled on output 12 to connect the bc-ir-emp infrared
receiever.
23.06.14 Vxx417