Technical data

brixlelektronik
...we got the solution
bc-12er 12 channel receiver bc-20 plus 20 channel receiver
[Fail safe value] lost or the transmitter switch off
Warnbl. Hazard lights (both indicators on)
[Hazard lights]
Links Left indicator on
[Left]
Rechts Right indicator on
[Right]
Aus Both indicators off
[Off[]
Ebenenschalter A-z Defines the input device on the transmitter that
[Level control] enabled/controls the different levels
Ebenenestellung Defines on which level this output will work
[Level assignment] (use 3 position switch for proper control of the levels)
E+ 0+ A+ works on all levels
E- 0- A+ works just in the upper level(switch up)
E- 0+ A- works just in the mid level(sw. Mid position)
E+ 0- A- works just in the lower level (switch down)
Gegenläufig Nein Normal operation
[Reverse] [no]
Ja/Invers Reverse option (US indicator style)
[Yes/Reverse]
Lenkkanal(Sender) A..z Defines the input device that stops the indicator.
[Steering channel] (Steering stick)
Ein Zeit 1..500 Defines the on-time of the indicator
[On time]
Aus Zeit 1..500 Defines the off-time of the indicator
[Off time]
Funktion: Blinker Rechts [Feature: Indicator Right]
This feature defines the output for the indicator on the right side
Blink.links ist 1..12 Indicator left is on output? [Reqired to link both
indicators)
Funktion: Eingang Schalter/Signal [Feature: Input Switch/Signal]
A switch or a signal can be fed in the bc-12er. Depending on the voltage/signal on
this input the modules can use this like an input from the transmitter. 0V will create
-125% and voltages higher than 2V will create +125% on the assigned letter. n-z
can be used on the same bc-12er module and n-x will be transmitted also to
23.06.14 Vxx417