Technical data

D Sound module USM-RC-2
60 BEIER-Electronic 01.03.2012
Configuration – output sequences
All outputs that have been allocated in the output configuration (see page 59) of an
output sequence, automatically appear here in the respective table. If the outputs do
not yet appear in the tables, you must first assign the desired outputs to the function
“Output sequence 1/2".
Total steps
For each of the 2 sequences, the number of steps can be set here. In each case, up
to 36 steps are possible.
If you enable the sequence, the steps will start with step 1 and run sequentially.
In each step you can now set for every output the desired intensity. For this purpose,
click with the mouse on the value that you want to change and select in the drop-
down box the new value (0% - 100%).
Likewise the duration for each step can be specified between 10ms and 2550ms.
Loop start and loop end
Similar to the three-stage additional sounds, the complete sequence can
be divided
into 3 sections:
1. Start sequence
2. Loop
3. Stop sequence
In the table, these 3 sections are stored colored in red and green for easy
identification.
First the start sequence (red) is shown when turning on the ouput sequence and then
the loop (green) as long as the sequence is still active. If the sequence is turned of,
still the stop sequence (red) will be shown at the end.
Loop start and loop end, can be set to any size. If the three-stage option should not
be used, the loop start must be set to one and loop end to the number of set steps in
order to make the whole sequence run through.
Stop immediately