Technical data
D Sound module USM-RC-2
01.03.2012 BEIER-Electronic 59
Configuration - outputs
Function
Here you can assign the 12 switching-outputs to various functions (see page 39).
Intensity
The intensity can be set in 5%-steps for every output. Except for the output
sequences 1 and 2, there the intensity is directly set in the sequence.
Option 1 and option 2
Several values can still be adjusted for some output types. For details, see the
description of the outputs starting at page 39.
Output options
If the selection „Brake light always on at stationary“ is activated, the brake light is
always turned on whenever the model is standing.
An adjustable afterglow of the brake light can also be activated.
If the selection „Hazard light automatically on when reversing“ is activated, the two
indicator lights are always on, once the model is reversing.
It can even be specified that indicators will turn off automatically after a certain
number of flashes. This automatic indicator shut-off does not work when activating
the turn signals using:
• Proportional channels as „static“
• Nautic mode without memory function
• Switching-inputs
If the „American indicator mode“ is activated, the indicators will always light when the
parking light is on.
The flashing rate for the indicators can be set, too. The values for „on“and „off“,
multiplied by 10ms, is the duration of the light and dark phases of the turn indicator.
If the function “Light flickering when starting“ is activated, all 12 outputs will flicker
while the starting noise (coldstart or warmstart) is played.