Technical data

D Sound module USM-RC-2
01.03.2012 BEIER-Electronic 39
Switching-outputs
The sound module has 12 outputs, which can be used to drive electrical consumer
units such as lamps, light-emitting diodes, relays etc. Different switching functions
can be attached to the 12 outputs by using the Sound-Teacher. (see page 59).
The outputs 11 and 12 are internally connected in parallel to both servo outputs of
the sound module. If the servo outputs are activated in the sound teacher, it is not
allowed to connect anything to the corresponding switching output!
The sound module is always switching the negative pole to each output and thus to
the connected load (e.g. LED, lamp, relay). The positive pole is always connected
permanently to the load.
The intensity (PWM-control) of each output can be configured with the Sound-
Teacher by steps of 5%, between 5% and 100%.
Following functions are possible:
output static on
output flashing
output as pulse
output flickering (sound dependend)
parking light
low beam headlight
high beam headlight
front fog light
rear fog light
brake light
reversing light
indicator right
indicator left
combined headlight
combined rear light
in motion on
in stationary on
at accelerating on
at driving speed on
output sequence 1
output sequence 2
Output “Static“ on
An output with this setup can be switched on using a sound, a proportional channel, a
nautic switch, the EKMFA-mode or a switching-input.
The output is always switched on as long as a sound is played, with which the output
is activated in the Sound-Teacher or the output is switched on with one of the free
allocable functions.