ATEX ABSOLUTE SSI MULTI TURN ENCODER, PAUX RANGE
ELECTRICAL CHARACTERISTIC
Input signal clock CLK per opto-coupler Power supply 5 – 30Vdc
Output signal DATA line - driver RS422 Introduction < 1 s
Clock frequency CLK 100kHz – 500kHz Cons. without load < 100mA (typically 50-60mA at 24Vdc)
Precision ± ½ LSB (13 bits) Position refresh < 200µs
SSI TRANSMISSION
Transmission
Transmission up to 400m* at
100kHz in function of the cable
characteristics
Cable
High security of transmission by
using shielded cable and twisted
pairs
*Consult us for length > 100m
SSI CONNECTION
Type Vcc Gnd Clk+ Data+ RAZ Data- Clk- DIRECTION
S5
BN/GN
Brown/Green
WH/GN
White/Green
GN
Green
GY
Grey
BU
Blue
PK
Pink
BN
Brown
WH
White
Note : Do not connect other pinouts, connect DIRECTION and RAZ to a potential (RAZ at 0V if not used)
ORDERING CODE
Shaft Supply Output stage Code
Resolution
Number of turns
Connection
Connection
Orientation
PEUX
(stainless steel)
PAUX
(aluminium)
30:30 mm P : 5-30Vdc
SS : SSI without parity
SP : SSI with even parity
SI : SSI with odd parity
B: Binary
G : Gray
13B12D5 :
Resolution : 13 bits
Number of turns : 12 bits
D5: 25bits frame
S5: cable
gland +
cable
Example :
R030 : radial
cable 3m
PEUX _ 30 // P SS G //
13 B12 D5 // S5 R030
ASSEMBLY CAUTION
NEVER OPEN THE ENCODER
NEVER CONNECT/DISCONNECT UNDER POWER SUPPLY/IN PRESENCE OF DUSTS ATMOSPHERE
The customer obliges to take up and to use our products, according to our specifications and to the manners of the profession. Our
company would not be responsible for any defect resulting from a defective or erroneous assembly. From a use superior to the
standard, or in abnormal conditions. The breakdowns resultant of shocks, bad electric supply, put in low capacity or overcapacity
of the product, the environment of bad conditions (humidity, projection, dust, etc) cannot be imputed to us. The converter doesn’t
require any maintenance. Any encoder presenting a dysfunction will have to be the object of immediate return for control in our
facilities. The encoder mustn’t be open in any case (cable gland and/or cover).
An earth situated on the cover must be linked with the ground of the installation.
Made in FRANCE
Changes possible without further notice - Version 100531