Absolute rotary encoder to master: Confirmation
CAN ID MAC ID Service Code
Byte0 Byte1
41B 0A 90
7.2.3. Total resolution
A
fragmented transmission is needed, when
the total resolution must be sent to the en-
coder.
So here are more messages necessary.
Master to Absolute Rotary Encoder:Set-Parameter
CAN ID MAC ID Fragment Service
Code
Class
ID
Instance
ID
Attribute
ID
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7
41C 8A 00 10 23 01 72 X X
Absolute Rotary Encoder to Master:Confirmation
CAN ID MAC ID
Byte0 Byte 1 Byte 2
41B 8A C0 00
Master to Absolute Rotary Encoder:Set-Parameter
CAN ID MAC ID Frag-
ment
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7
41C 8A 81 X X - - - -
X: desired total resolution
Absolute Rotary Encoder to Master:Confirmation
CAN ID MAC ID
Byte0 Byte 1 Byte 2
41B 8A C1 00
Absolute Rotary Encoder to Master:Confirmation
CAN ID MAC ID Service Code
Byte0 Byte1
41B 0A 90