User Manual
DEVICE NET USER MANUAL
B
EI IDEACOD SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél : +33 (0)3 88 20 80 80
Fax : +33 (0)3 88 20 87 87
Mail : info@bei-ideacod.com
Web : www.bei-ideacod.com
4.3. Saving Parameter
The parameters of the absolute rotary en-
coder are saved in a non-volatile FLASH
memory. Because of a limited number of writ-
ing cycles ( 1,000), it is useful to transmit the
modified parameter in the first step only in the
RAM area. After adjusting and examination,
those values can be saved in the FLASH mem-
ory. After successful saving of the parameter
the encoder sends his MAC-ID on the bus. To
get the process value a new allocation of the
slave is required.
Example:
(MAC-ID Master: 0A hex, MAC-ID Slave: 03
hex)
5. Transmission of the actual position
The process value is transmitted according to
the following table.
CAN-ID process value
11 Bit Byte 0 Byte 1 Byte 2 Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
Byte
Offset
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
Frag [0] XID MAC ID
1 R/R [0] Service [32]
Class ID [23]
Instance ID [01]
CAN-ID Byte 0 Byte 1 Byte 2 Byte 3
41C 0A 32 23 01
Version 05/04 UME-OCD-D2 Page 11