Owner's manual

Version 07/10 BEI Sensors CANopen Manual serie M 30
Subindex Description Data Type Default Value Access Restore after
BootUp
0 - Unsigned 16 0 rw yes
Object 100Dh: Life Time Factor
T
his object contains the life time factor parameters. The life time factor multiplied with the guard time gives
the life time for the node guarding protocol.
Subindex Description Data Type Default Value Access Restore after
BootUp
0 - Unsigned 8 0 rw yes
Object 1010h: Store Parameters
T
his object is used to store device and CANopen related parameters to non volatile memory.
Subindex Description Data Type Default Value Access Restore after
BootUp
0 Number of sub indices Unsigned 8 2 ro no
1 Store all parameters Unsigned 32 “save” rw no
Storing procedure
To save the parameters to non volatile memory the access signature “save” has to be sent to the
corresponding subindex of the device.
Most significant word Least significant word
ASCII E v a s
Hex value 65h 76h 61h 73h
Object 1011h: Restore Parameters
T
his object is used to restore device and CANopen related parameters to factory settings.
Subindex Description Data Type Default Value Access Restore after
BootUp