Owner's manual

Version 07/10 BEI Sensors CANopen Manual serie M 11
CAN Run LED State Description
Flickering AutoBitrate/ LSS The auto-bitrate detection is in progress or LSS services are in
progress (alternately flickering with run LED)1
Blinking PREOPERATIONAL The device is in state PREOPERATIONAL
Single flash STOPPED The device is in state STOPPED
Double flash Reserved for further use
Triple flash Program/ Firmware
download
A software download is running on the device
On OPERATIONAL The device is in state OPERATIONAL
Tab.3: CAN Run LED states
ERR LED State Description
Off No error The device is in working condition
Flickering AutoBitrate/ LSS The auto-bitrate detection is in progress or LSS services are in
progress (alternately flickering with run LED)1
Blinking Invalid
Configuration
General configuration error
Single flash Warning limit
reached
At least one of the error counters of the CAN controller has
reached or exceeded the warning level (too many error frames)
Double flash Error control
event
A guard event (NMT-slave or NMT-master) or a heartbeat event
(heartbeat consumer) has occurred
Triple flash Sync error The sync message has not been received within the configured
communication cycle period time out (see object dictionary entry
1006
h)
Quadruple
flash
Event-timer
error
An expected PDO has not beenreceived before the event-timer
elapsed
On Bus off The CAN controller is bus off
Tab.4: CAN Error LED states