User Manual
24
Figure (5) CONTROL SWITCH SETTINGS COMMAND
Internal Dip-Switch (S1): Switch 1, 3, and 4 are “OFF”; Switch 2 is “ON”
DECIMAL 7 (far left digit): “1”
DECIMAL 6, DECIMAL 5, DECIMAL 1 (far right digit): Does Not Matter
DECIMAL 4
INPUT NUMBER
ROTARY POT
POWER ADJUST
ENABLED
VSWR FOLDBACK
DISABLED
REVERSE POWER
CALIBRATION
ENABLED
0No
No No
1No
No
Yes
2NoYes
No
3NoYesYes
4 Yes No No
5
Yes No
Yes
6
Yes
Yes
No
7
Yes
Yes Yes
8No
No No
9No
No
Yes
Note: Entries in bold italics are standard default from factory. A “4” input will set all three controls to default.
DECIMAL 3
INPUT NUMBER
FORWARD POWER
CALIBRATION
ENABLED
HI TEMPERATURE
SHUTDOWN
DISABLED
0NoNo
1NoNo
2
No
Yes
3
No
Yes
4Yes
No
5Yes
No
6YesYes
7YesYes
8NoNo
9NoNo
Note: Entries in bold italics are standard default from factory. A “0, 1, 8, or 9” input will set both controls to
default.
DECIMAL 2
INPUT NUMBER
DIRECT
FREQUENCY
CHANGE ENABLED
CHANNEL
FREQUENCY
CHANGE ENABLED
0NoNo
1No
Yes
2
Yes
No
3YesYes
4NoNo
5No
Yes
6
Yes
No
7YesYes
8NoNo
9No
Yes
Note: Entries in bold italics are standard default from factory. A “3 or 7” input will set both controls to default.