Quick Start Manual

42
13
14
5.3.5 Start-up
In the “TX control panel” screen, rotate the encoder until it selects the second tab of the
horizontal menu to turn it on.
Press the encoder until the RFON message appears.
In LOCAL mode the following must occur to have a compliant situation:
The 4 warning lights (ITLK, -3dB, CLIP, NOAU) must be off;
The frequency set must be the desired one;
The direct power must be the desired one;
The reflected power must be null or low level;
The Vu-Meters must be set to 0dB.
At the end of the installation and programming steps, switch the equipment to REMOTE
mode by using the key switch.
In this mode the following must occur to have a compliant situation:
The PLL LOCK LED must be on;
The ON AIR LED must be on;
The MAINS LED must be on;
All remaining LEDs must be off;
The display shows the corporate logo if the “SHOW D. : LOCAL” setting is present;
the display will show the scrolling menu tree if the “SHOW D. : ALWAYS” setting is
present.
Warning: it is recommended to keep a copy of the key switch in a safe place in the
workstation.
Quick instructions for commissioning