Front Panel Features 2
The main assembly front panel contains LED indicators for the system controller, internal
exciter, internal power amplifier, and an LCD user interface.
Figure 1 – Main Assembly Front Panel
2.1 FAILSAFE
The failsafe LED is coupled directly to the failsafe input on the back panel. Green indicates
the failsafe is connected for normal operation. If red the failsafe is not connected and RF
power will not turn on.
2.2 AUDIO
The audio LED indicates the status of the current primary audio source. If an audio peak
silence condition is detected, this LED turns red. The LED remains green until a failure is
detected. Check the exciter diagnostics for details on what alarms or faults may be active.
2.3 EXC DRV
The exciter drive LED indicates the status of any alarms or faults related to the exciter. Green
indicates that the exciter has settled into normal operating conditions. Orange indicates an
alarm condition. Red shows when the exciter has a fault condition. See Table 2 – Exciter
Diagnostics Details in section 7.5 for more information.
Note that there is overlap between internal exciter and internal PA status for drive detection.
An exciter drive alarm indication may originate from the PA. The exciter must also establish
frequency lock as it powers up. These are intended to indicate conditions that prevent full
operation whether the conditions are expected or not. Check the exciter and PA diagnostics
for details on what alarms or faults may be active.