16 17FEEDBACK DESTROYER FBQ1000 Quick Start Guide
FEEDBACK DESTROYER FBQ1000 Preset chart
Preset Filter 1 Filter 2 Filter 3 Filter 4 Filter 5 Filter 6 Filter 7 Filter 8 Filter 9 Filter 10 Filter 11 Filter 12
1 MONO: 9 single shot lters attenuate room resonances before 3 automatic lters destroy variable feedbacks
L SI SI SI SI SI SI SI SI SI AU AU AU
R SI SI SI SI SI SI SI SI SI AU AU AU
2 2 x MONITOR AS FEEDBACK DESTROYER ONLY: 7 single shots / 5 automatic lters for most monitor setups
L SI SI SI SI SI SI SI AU AU AU AU AU
R SI SI SI SI SI SI SI AU AU AU AU AU
3 MONO AUTO PILOT: 12 Filters per channel constantly chase and destroy feedbacks
L AU AU AU AU AU AU AU AU AU AU AU AU
R AU AU AU AU AU AU AU AU AU AU AU AU
4 STEREO PARAMETRIC EQ: Preset with 12 ISO frequencies, all set to 1/3 Oct., Gain + 0 dB
Couple 125 Hz 160 Hz 200 Hz 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz 1 k 1.25 k 1.6 k
5 STEREO PARAMETRIC EQ: Preset with 12 ISO frequencies, all set to 2/3 Oct., Gain + 0 dB
Couple 40 Hz 63 Hz 100 Hz 160 Hz 250 Hz 400 Hz 630 Hz 1 k 1.6 k 2.5 k 4 k 6.3 k
6 2 x MONO: Sample monitoring, left for handheld (lead) microphone(s), right for xed (backing) ones
L SI SI SI AU AU AU AU AU PA def PA def PA def PA def
R SI SI SI SI SI AU AU AU PA def PA def PA def PA def
7 MONO PARAMETRIC AND SINGLE SHOT FILTERS: A good start for a monitor equalization
L SI SI SI SI SI SI SI SI PA def PA def PA def PA def
R SI SI SI SI SI SI SI SI PA def PA def PA def PA def
8 STEREO FOH EQ, providing 4 parametric EQ's (low roll o in lter 1 and 2), plus 8 single shot lters
Couple
PA PA PA d. PA d. SI SI SI SI SI SI SI SI
40 Hz 80 Hz
Channels coupled, changes on one channel are valid for both1 Oct. 1 Oct.
-8 dB -4 dB
9 MONO FREE
L SI SI SI SI SI SI SI AU AU PA PA PA
R SI SI SI SI SI SI SI AU AU PA PA PA
10 STEREO: libre.
Couple SI SI SI SI SI SI SI AU AU PA PA PA
Preset Filtro 1 Filtro 2 Filtro 3 Filtro 4 Filtro 5 Filtro 6 Filtro 7 Filtro 8 Filtro 9 Filtro 10 Filtro 11 Filtro 12
1 MONO: 9 Filtros Single Shot + 3 Filtros Automatic para la eliminación de realimentaciones variables.
L SI SI SI SI SI SI SI SI SI AU AU AU
R SI SI SI SI SI SI SI SI SI AU AU AU
2 MONO: 7 Filtros Single Shot 5 Filtros Automatic para su uso en sistemas de monitorización.
L SI SI SI SI SI SI SI AU AU AU AU AU
R SI SI SI SI SI SI SI AU AU AU AU AU
3 MONO: 12 Filtros en modo Automatic para localización y supresión de realimentaciones.
L AU AU AU AU AU AU AU AU AU AU AU AU
R AU AU AU AU AU AU AU AU AU AU AU AU
4 STEREO: EQ paramétrico con las 12 frecuencias ISO con un ancho de banda de 1/3 octava y 0 dB de ganancia.
Couple 125 Hz 160 Hz 200 Hz 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz 1 k 1.25 k 1.6 k
5 STEREO: EQ paramétrico con las 12 frecuencias ISO con un ancho de banda de 2/3 octava y 0 dB de ganancia.
Couple 40 Hz 63 Hz 100 Hz 160 Hz 250 Hz 400 Hz 630 Hz 1 k 1.6 k 2.5 k 4 k 6.3 k
6 MONO: Ejemplo de eliminación de realimentaciones; izquierdo para micrófonos manuales (solista) y derecho para jos (coro).
L SI SI SI AU AU AU AU AU PA def PA def PA def PA def
R SI SI SI SI SI AU AU AU PA def PA def PA def PA def
7 MONO: Filtro paramétrico + Single Shot. Buen punto de partida para ecualización de monitor.
L SI SI SI SI SI SI SI SI PA def PA def PA def PA def
R SI SI SI SI SI SI SI SI PA def PA def PA def PA def
8 STEREO: FOH-EQ. 4 ltros paramétricos (Pasa-altos en los ltros 1 y 2) + 8 ltros Single Shot.
Couple
PA PA PA def PA def SI SI SI SI SI SI SI SI
40 Hz 80 Hz
Los canales se encuentran en modo Couple.1 Oct. 1 Oct.
-8 dB -4 dB
9 MONO: libre.
L SI SI SI SI SI SI SI AU AU PA PA PA
R SI SI SI SI SI SI SI AU AU PA PA PA
10 STEREO: libre.
Couple SI SI SI SI SI SI SI AU AU PA PA PA