Version 1.
EUROLIGHT LC2412 IMPORTANT SAFETY INSTRUCTIONS DETAILED SAFETY INSTRUCTIONS: 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. CAUTION: WARNING: To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside; refer servicing to qualified personnel. To reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture.
EUROLIGHT LC2412 EUROLIGHT Professional 24-channel DMX lighting console s Up to 3 DMX channels can be controlled per preset channel s 120 scenes storable in 10 banks LC2412 s 24 preset channels, assignable to 512 DMX channels s Integrated chaser with up to 650 steps featuring sync-to-bass beat s Frequency-dependent sound-to-light function s Crossfade time freely selectable for super-smooth scene fades s Two additional, multi-functional channels for special effects (e.g.
EUROLIGHT LC2412 TABLE OF CONTENTS FOREWORD Dear Customer, welcome to the team of BEHRINGER users, and thank you very much for expressing your confidence in us by purchasing the EUROLIGHT LC2412.
EUROLIGHT LC2412 7. ADDITIONAL FUNCTIONS OF THE LC2412 ............. 17 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 Locking program mode ............................................... 17 Putting the output on hold ........................................... 17 Special channels ......................................................... 17 Theater mode .............................................................. 17 7.4.1 Activating theater mode ................................... 17 7.4.
EUROLIGHT LC2412 Comparable to a mixing console in a recording studio, a light mixing console is a switching central for stage lighting. Therefore, a light mixing console has to be absolutely reliable and under no circumstances leave you stranded. We created our LC2412 using the most modern components in order to guarantee you the maximum reliability possible. But without functionality, no amount of reliability is of use to you.
EUROLIGHT LC2412 Fig. 2.1: Section overview 2.1 Control elements of the A PRESET section Fig. 2.2: A PRESET section (detail) Faders 1-12. Used to set the intensity of light elements connected to the dimmer pack. UPPER switch. When you press this switch, the A PRESET section is switched to the twelve additional channels. After that, you can set up the intensity of channels 13 - 24. See also chapter 3.2.
EUROLIGHT LC2412 UP/DOWN keys. Use them to select a preset bank (0 - 9) or switch into preset mode (P). The control lights flash when you select a new bank while memories from the previous bank are still active (the fader(s) is(are) pulled , ) down to fade the up). Pull the fader(s) ( memory out. When you pull the fader(s) up again, the memory of the new preset bank is visible on the stage (also see chapter 4.1.2).
EUROLIGHT LC2412 2.5 Control elements of the programming section Despite its compact size, the EUROLIGHT LC2412 is a versatile light mixing console. In it, we have integrated a plethora of functions, among others, various functions for memories, chases and digital control. The basic elements of the programming section are located at the top right section of the unit. To let you quickly orient yourself in difficult situations, the LC2412 also features a display.
EUROLIGHT LC2412 MAIN fader. It determines the maximum illumination level of all commands at the consoles output. mode is active). More detailed information on this subject can be found in chapters 6.2.3 and 7.4. PRESET FLASH key. You can execute the entire A PRESET section with this flash key, that is, activate the A PRESET section on the stage, even if the the A fader is fully down. As soon as you let go of the key, the lights fade again. More information about this subject is found in chapter 4.3.
EUROLIGHT LC2412 3.1 Basic configuration Pull all the faders all the way down to the zero mark. This way, you assure that you start your exploration of the possibilities of the LC2412 from a neutral setting, and can observe the results of the changes you implement directly. Use the POWER switch to power up your BEHRINGER EUROLIGHT LC2412. The LC2412 displays now the setup that was most recently used, just prior to being powered down last time. Fig. 2.11: Serial number and mains connector SERIAL NUMBER.
EUROLIGHT LC2412 2. Now, set up the lighting situation by using the faders of the B MEMORY section. As always, you can observe these changes on the control LEDs. 3. Move the master B fader downward, then move the master A fader upward. Preset B is faded out, while preset A is faded in (manual fade). 4. THE B MEMORY SECTION In this context, memory means a lighting situation (preset) stored as a unit.
EUROLIGHT LC2412 3. Now pull fader B down and fader A up. The preset appears at the console output, while the memories dissappear. 4.2.2 Crossfading between memories There are several ways to crossfade between memories: Crossfading steplessly using the FLASH keys Please take the following required steps, as follows: 1. Disengage the CHANNEL FLASH key ; / keys). The memory is faded in. You determine the illumination level by using the CHASE and the MAIN fader.
EUROLIGHT LC2412 4.5 Previewing memories individually on the stage (live mode) Live mode gives you the option to preview individual memories and chases on the stage, without having to interrupt the program currently running. Therefore, live mode changes the usual sequence of events that allows you to run a show on the stage while previewing and editing chases and memories in the background by using the control LEDs.
EUROLIGHT LC2412 Table 6.1 shows the necessary setup: Key On INSERT MANUAL Fig. 6.3: Display programming memory chase SOUND The displays indicates the memory and the storage bank in which the selected memory is located. Example: STEP: 01 09 (memory) RUN 04 (bank). Off Table. 6.1: Chase control through sound 5. Confirm your choice with SOFT A (ENTER). 6. Enter as many memories as you wish following the same procedure (max. 99 steps). 7.
EUROLIGHT LC2412 Insert If you additionally activate the INSERT key, you can crossfade between the two most recently selected steps. + + If you are currently playing a chase, you can pause it by pressing the INSERT key. Pressing the INSERT key for the second time restarts the chase again. INSERT and MANUAL can also be used in SOUND and RUN modes.
EUROLIGHT LC2412 6.4 Previewing chases in live mode 7.3 Special channels You can use the live mode for chases as well. More detailed information about live mode can be found in chapter 4.5. Both special channels and are well-suited activating effects independently from other settings of the EUROLIGHT LC2412. Fog machines, color changers or disco ball motors are such effects. You can program special activation modes for these effects. To preview chases in live mode, do the following: 1.
EUROLIGHT LC2412 7.4.2 Programming fading times in theater mode Since theater mode presents a special kind of chases, it also uses the menu and chase controls to program steps. Similarly, theater mode sequences are stored as chases. To program steps for a chase in theater mode, do the following: 1. Activate the theater mode, as described previously. 2. Press the CHASE key and select a chase. 3. Select LEVEL or MEMORY. 4. Modify the desired step or select a memory. 5. Press the SOFT A key for ENTER.
+ + EUROLIGHT LC2412 Attention: Storing data on a storage location that already contains some data automatically replaces this data. Similarly, the data on the consoles memory is replaced when you transmit the data from the memory card. If you wish to keep this data, make sure to first store it to a memory card. 8. DIMMER CONTROL Since the LC2412 uses its own data format, once you format a memory card on it, you can no longer read this card on a PC! 7.
EUROLIGHT LC2412 uses this standard (even if it is done with partially different plugin connectors), your EUROLIGHT LC2412 is therefore extremely flexible in how it can be implemented. To assign the desired DMX channels to individual console channels (or to preview the assignment of channels), go through the following steps: A big advantage of digital control is its enourmously simplified cabling, since you only need one single cable for transmitting control data.
EUROLIGHT LC2412 9.3.3 MIDI connection 9.1 Cables recommended for DMX512 The cables should be manufactured according to EIA-485 or EIA-422 specifications. Using shielded, twisted, double-stranded data transmission cables is recommended. For example, these are the same cables used for transmitting digital audio data in the AES/EBU format. You can also implement lines with a second wire set, used as a replacement in case of a malfunction.
EUROLIGHT LC2412 10. SPECIFICATIONS CHANNELS DMX 26 (24 + 2 special switchable channels) 78 out of 512 DMX channels (max. 3 DMX channels per consolechannel) MEMORIES max. 120 CHASES Steps max. 99 max. 650, up to 99 per chase INPUTS Analog In Level 1/4" TS mono jack connector, unbalanced Line level Footswitch 1/4" TS mono jack connector MIDI In DIN 5-pole connector OUTPUTS DMX512 out MIDI out Analog out Level Min.
EUROLIGHT LC2412 11.
EUROLIGHT LC2412 12. WARRANTY § 1 WARRANTY CARD/ONLINE REGISTRATION To be protected by the extended warranty, the buyer must complete and return the enclosed warranty card within 14 days of the date of purchase to BEHRINGER Spezielle Studiotechnik GmbH, in accordance with the conditions stipulated in § 3. Failure to return the card in due time (date as per postmark) will void any extended warranty claims.
FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION EUROLIGHT LC2412 Responsible party name: MUSIC Group Services USA, Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.: Phone: +1 425 672 0816 Fax: +1 425 673 7647 EUROLIGHT LC2412 complies with the FCC rules as mentioned in the following paragraph: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.