SDS
ACGIH Biological Exposure Indices
ValueComponents Determinant Specimen Sampling Time
0.03 mg/l Toluene Urine
*
0.02 mg/l Toluene Blood
*
1.5 g/g Methylhippuric
acids
Creatinine in
urine
*
Xylene (CAS 1330-20-7)
* - For sampling details, please see the source document.
Explosion-proof general and local exhaust ventilation. Good general ventilation should be used.
Ventilation rates should be matched to conditions. If applicable, use process enclosures, local
exhaust ventilation, or other engineering controls to maintain airborne levels below recommended
exposure limits. If exposure limits have not been established, maintain airborne levels to an
acceptable level. Provide eyewash station.
Appropriate engineering
controls
Individual protection measures, such as personal protective equipment
Wear safety glasses with side shields (or goggles).
Eye/face protection
Skin protection
Wear appropriate chemical resistant gloves.
Hand protection
Skin protection
Wear suitable protective clothing. Use of an impervious apron is recommended.
Other
If airborne concentrations are above the applicable exposure limits, use NIOSH approved
respiratory protection. Use a positive-pressure air-supplied respirator if there is any potential for an
uncontrolled release, exposure levels are not known, or any other circumstances where
air-purifying respirators may not provide adequate protection.
Respiratory protection
Wear appropriate thermal protective clothing, when necessary.
Thermal hazards
Observe any medical surveillance requirements. When using do not smoke. Always observe good
personal hygiene measures, such as washing after handling the material and before eating,
drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove
contaminants. Contaminated work clothing should not be allowed out of the workplace.
General hygiene
considerations
9. Physical and chemical properties
Appearance
Liquid.
Physical state
Liquid.
Form
Clear.
Color
Solvent odor.
Odor
Odor threshold
Not available.
pH
Not available.
Melting point/freezing point
Not available.
Initial boiling point and boiling
range
298.4 - 379.4 °F (148 - 193 °C)
Flash point
> 100.4 °F (> 38.0 °C)
Evaporation rate
Slower Than Ether
Not available.
Flammability (solid, gas)
Upper/lower flammability or explosive limits
Flammability limit - lower
(%)
Not available.
Flammability limit - upper
(%)
Not available.
Vapor pressure
Not available.
SDS US
BEHR Oil-Based Fast-Drying Polyurethane Semi-
Gloss 951177 Version #: 00 Revision date: 12-4-19
Issue date: 11-22-19
5 / 10