INTERIOR CEILING FLAT PAINT
NO. 558 ULTRA PURE WHITE®
PRODUCT INFORMATION
BEHR PREMIUM PLUS® Interior Ceiling Flat Paint is a premium quality acrylic latex at nish paint formulated to resist
splatter when applied to interior textured, popcorn and acoustic style ceilings. This at nish helps to hide minor surface
imperfections and provides great coverage.
RECOMMENDED USES:
Use on properly prepared, interior ceilings including:
• Drywall/Gypsum Board • Plaster
• Concrete
• Wood
PRODUCT SPECIFICATIONS:
Tint Bases/Max Tint Load:
No. 558 128 oz. / 2 oz.
Gloss: 0-2 @ 60°
Sheen: 0-3 @ 85°
Resin Type: Acrylic Latex
Weight per Gallon: 12 lbs.
% Solids by Volume: 35.5%
% Solids by Weight: 54.5%
VOC: <50 g/L
Flash Point: N/A
Viscosity: 92-102 KU
Recommended Film Thickness:
Wet: 6.4 Dry: 2.2 mils @ 250 Sq. Ft./Gal.
Wet: 4.0 Dry: 1.4 mils @ 400 Sq. Ft./Gal.
Coverage: 250-400 Sq. Ft./Gal. depending on application
method and substrate porosity. Does not include the loss
of material from spraying.
APPLICATION:
Brush: Nylon/polyester
Roller:
Smooth Surface: 3/8" - 1/2" nap
Rough Surface: 1/2" - 3/4" nap
Airless Spray: At packaged consistency
Tip: .015"- .019"
Filter: 60 mesh
Thinning: (If required) No more than 1/2 pint
of water per gallon.
Dry Time: @ 77° & 50% RH
Longer dry time may be required in cooler temperatures
and higher humidity.
To Touch: 1 hour
To Recoat: 2 hours
Full Cure: 4 weeks
SURFACE PREPARATION:
All surfaces must be clean, free of dust, chalk, oil, grease,
wax, polish, mold and mildew stains, loose and peeling
paint, rust and all other foreign substances.
New Drywall: All drywall surfaces should be suciently
sanded smooth. Remove any remaining drywall dust prior
to priming. Allow all drywall compounds to be completely
dry prior to coating. Previously Painted Drywall: Remove
all loose and peeling paint and all other foreign substances.
Clean any dirt and grease by scrubbing the surface with
a detergent and water solution, followed by a thorough
rinsing with clean water. Set nails and ll holes, scratches,
and gouges with the appropriate spackling material. Let dry
completely and sand smooth. Remove all dust with a wiping
cloth. Fill all gaps with a 100% acrylic, siliconized, paintable
caulking, and allow to completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the surface
thoroughly before coating.
New Wood: Remove mill glaze with sandpaper. Set nails and
ll holes, scratches, and gouges with the appropriate wood
ller and let dry completely. Remove all dust with a wiping
cloth. Fill all gaps with a 100% acrylic, siliconized, paintable
caulking, and allow to completely dry prior to coating.
Previously Painted Wood: Remove all loose and peeling
paint and all other foreign substances. Clean any dirt and
grease by scrubbing the surface with a detergent and water
solution, followed by a thorough rinsing with clean water.
Set nails and ll holes, scratches, and gouges with the
appropriate wood ller and let dry completely.
Remove all dust with a tack or wiping cloth. Fill all
gaps with a 100% acrylic, siliconized, paintable
caulking, and allow to completely dry prior to coating.
Glossy Surfaces: For maximum adhesion, sand the
surface thoroughly before coating.
Wood: WARNING! Sanding or scraping pressure treated
lumber may be hazardous; wear appropriate protection.
New Plaster: New plaster should be thoroughly dried
out and cured for a minimum of 30 days before painting.
When cured, clean using a mixed solution of one part
vinegar and one part water to remove eorescence and
neutralize. Previously Painted Plaster: Remove all
loose and peeling paint and all other foreign substances.
Clean any dirt and grease by scrubbing the surface with
a detergent and water solution, followed by a thorough
rinsing with clean water. Set nails and ll holes, scratches,
and gouges with the appropriate spackling material. Let dry
completely and sand smooth. Remove all dust with a tack
or wiping cloth. Fill all gaps with a 100% acrylic, siliconized,
paintable caulking, and allow to completely
dry prior to coating. Glossy Surfaces: For maximum
adhesion, sand the surface thoroughly before coating.
Stainblocking: After priming, test for stain bleed-through.
If the stain bleeds through the topcoat, apply a second coat
of primer and test again before top-coating the entire area.
If bleeding continues, a longer dry time of the primer may be
needed before top-coating.
Masonry: All masonry surfaces must be cured at least
30 days before painting. The pH must be 10.0 or lower
prior to coating. Smooth masonry may require an adequate
prole for adhesion. For all other smooth trowel concrete,
create a prole using a concrete etcher.
Ferrous and Non-Ferrous Metal: The oil lm on new
galvanized metal must be removed before it is painted.
Remove oil lm with a detergent and water solution.
For better paint adhesion, sand the surface with sandpaper,
steel wool, or by using a product with muriatic acid.
Clean, by scrubbing the surface with a detergent and water
solution, followed by a thorough rinsing with clean water.
COMPLIES WITH THE BELOW AS OF 1/1/2017
SCAQMD YES LEED v.3 (2009)
YES
CARB YES LEED® v.4 YES
OTC YES GREENGUARD® YES
LADCO YES CHPS YES
AIM YES
This coating conforms to USDA regulatory requirements
for incidental food-contact materials intended for use on
surfaces not in direct contact with food, such as walls, oors
and ceilings.
Please visit www.usgbc.org/LEED for additional details.
GREENGUARD is a registered trademark of UL Company.