Instruction Manual

Table Of Contents
REPLACEMENT ALUMINIZED PRIMARY HEAT EXCHANGER: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
5
A160110
Fig. 5 – Heat Exchanger Removal / Installation
A11414
Fig. 6 – Coupling Box/Sidewall Baffle Removal / Installation - Rear
View
4. Insert the screws that attach the sidewall baffles to the coupling
box.
Heat Exchanger Assembly Installation
1. Lift the heat exchanger assembly and set the rear of the assembly on
the blower deck.
2. Slide the heat exchanger onto the support rails in the furnace
casing.
3. Raise the rear of the heat exchanger and set the bottom of the
sidewall baffles on top of the support rails in the blower deck.
4. Slide the heat exchanger assembly into the casing, making sure the
bottom edge of the sidewall baffle slides into the engagement tab on
the support rails.
NOTE: Be sure cell panel insulation is folded over the top flange of the
primary cell inlet panel so that when the heat exchanger is fully installed,
the insulation seals between the top plate and the top flange of the cell
panel.
NOTE: Be sure the cell panel insulation is visible on both sides of the
heat exchanger cell panel so that when the heat exchanger is fully
installed, the insulation seals between the cell panel and the mounting
brackets. If any insulation is not visible, pull the heat exchanger forward,
adjust the insulation and reinstall so that the cell panel is properly sealed
to the top plate and to the mounting brackets.
5. Continue to slide the heat exchanger assembly backward into the
casing until the primary cell panel is flush with the mounting
brackets on the side of the casing.
6. Align the primary cell panel with the mounting brackets.
7. Insert the screws that attach the primary cell panel to mounting
brackets on the casing.
8. Align the filler plate to the bottom edge of the condensing heat
exchanger assembly.
9. Secure the filler plate to the condensing heat exchanger and casing.
Collector Box Installation
1. Verify old collector box gasket is reusable or obtain a new gasket
from the distributor (preferred).
2. Obtain new condensate trap gasket from distributor and install.
NOTE: There is a slot on each side of the front panel of the condensing
heat exchanger. The collector box has alignment tabs on the back that fit
into the slots on the condensing heat exchanger panel.
3. Align the tabs on the collector box to the slots on the condensing
heat exchanger panel.
4. With the collector box fully seated against the condensing heat
exchanger cell panel, install the screws through the collector box.
5. Tighten the screws in an alternating pattern around the collector
box. Do not over-tighten.
Install J-Box and Main Harness
1. Insert grommet for main harness in the slot in the blower shelf.
2. Align the door switch to the blower shelf.
3. Align and install door bracket to the front edge of the blower shelf
and secure the door switch during upper door bracket installation.
4. Connect the field wiring from the factory wiring and attach the
ground wire to the green ground screw on the J-Box bracket.
5. Attach the J-Box cover to the J-Box bracket.
6. Install the screw to secure the J-Box cover to the bracket.
7. Connect the factory wires to the main limit switch.
Install the Condensate Trap and Drain
NOTE: If the condensate trap is removed, a new gasket between the trap
and collector box is required. Obtain one from your local distributor.
1. Align the trap with the drain outlet on the collector box.
2. Secure the trap to the collector box with the screw.
3. Connect the condensate trap relief tube from collector box port and
insert the tube into the molded retainer clips on the inducer housing.
4. Insert the condensate drain elbow through the casing until it is
properly seated. Or, connect the drain elbow to the drain extension
pipe and route the pipe behind the inducer.
CELL PANEL
)52179,(:2)35,0$5<+($7(;&+$1*(5
5($59,(:2)+($7(;&+$1*(5
+($7(;&+$1*(5
&283/,1*%2;&29(5
&217$,10(17
3/$7(
%$))/(),1*(5
6HH'HWDLO*