Instruction Manual

Table Of Contents
REPLACEMENT ALUMINIZED PRIMARY HEAT EXCHANGER: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
Heat Exchanger Assembly Removal
1. Remove the screws that attach the filler plate to the bottom edge of
the condensing heat exchanger assembly and casing.
2. Remove screws that secure the heat exchanger assembly to the heat
exchanger mounting brackets.
3. Pull assembly out of casing until the back edge of the heat
exchanger assembly is resting on the front edge of the blower shelf.
4. Lift the heat exchanger assembly out of the casing and set aside.
Remove Coupling Box
1. Remove the screws that secure the finger baffle from the Coupling
Box Cover. See
Fig. 5.
2. Remove the screws that secure the Coupling Box Cover to the rear
of the Heat Exchanger Assembly.
3. Starting at the upper beveled edge of the coupling box, use a putty
knife or gasket scraper to get between the coupling box cover and
the Primary Cell Outlet panel to break the silicone seal between the
parts.
4. Pry upwards with the putty knife as you move around the Coupling
Box cover.
5. Once the Coupling Box cover is sufficiently loosened, remove the
coupling box cover from the rear of the Heat Exchanger Assembly.
See
Fig. 6.
6. Remove the screws that secure the Sidewall Baffles to the Primary
Cell Panel and set aside.
Separate Primary and Condensing Heat
Exchangers
1. Remove the screws that attach the condensing heat exchanger
assembly to the primary cell outlet panel and remove the screws
that attach the condensing heat exchanger outlet panel to the
primary inlet panel.
2. Gently use a putty knife or gasket scraper to get between the
primary cell inlet panel and condensing heat exchanger if it is
needed to break the seal between the parts.
3. Repeat the procedure at the primary cell outlet panel and
containment plate attached to the inlet of the secondary heat
exchanger.
Remove Primary and Condensing Heat Exchanger
NOTE: The primary heat exchanger assembly is factory- assembled at
primary cell attachment plate and the primary rear cell outlet panel. The
individual heat exchanger cells cannot be removed in the field and are
replaced as one assembly.
1. Remove screws that attach the sidewall baffles to the heat
exchanger cell panel. See Fig. 8.
NOTE: The front edge of the sidewall baffle has a slot that engages a tab
on the primary cell panel. See
Fig. 8.
2. Avoid damaging the cell panel insulation by pulling the sidewall
baffle outward from the rear of coupling box, then pull the baffle
backward to slide the baffle off of the locater tab on the cell panel.
3. Repeat the procedure for the opposite side baffle.
4. Remove the screws around each burner inlet opening that attaches
the heat exchanger cell panel to the primary inlet plate of the
primary heat exchanger assembly.
5. If not removed already, remove the screws that attach the primary
cell panel to the front of condensing heat exchanger section.
6. Separate the Primary Heat Exchanger from the Condensing Heat
Exchanger.
7. Remove the primary cell panel from the primary cell inlet plate and
set aside.
BEGIN RE-ASSEMBLY
Install Heat Exchanger Primary Cell Panel
1. Align the primary cell panel with the primary inlet plate of heat
exchanger assembly.
2. Avoid damaging the cell panel insulation during alignment.
3. Insert the screws around each burner inlet opening that attaches the
heat exchanger cell panel to the primary inlet plate of the primary
heat exchanger assembly. See
Fig. 5.
Attaching Primary and Condensing Heat
Exchangers
1. Align the bottom edge primary cell outlet panel with the top edge of
the condensing heat exchanger assembly, and align the top edge of
the condensing heat exchanger outlet panel with the bottom edge of
the primary cell inlet panel.
2. The orange foam gasket must be between the primary cell outlet
panel and the containment plate that is attached to the condensing
heat exchanger. The white fiber gasket or equivalent must be
between the primary cell inlet panel and the condensing heat
exchanger outlet panel. See Fig. 5.
3. Insert all the screws, except the outboard screws in the primary
outlet panel, to secure the primary heat exchanger panels to the
condensing heat exchanger panels (front and back). See
Fig. 5.
Install Coupling Box Cover/Finger Baffles
1. Apply a 1/4” bead of low adhesion silicone (white) to the coupling
box cover in the pattern shown in
Fig. 9.
2. Align the Coupling Box Cover over the rear of the Heat Exchanger
Assembly. See
Fig. 5 and Fig. 6.
3. Install the screws that secure the bottom edge and sides of the
Coupling Box to the Heat Exchanger Assembly.
4. Align the Finger Baffles along the top edge of the Coupling Box
Cover. See
Fig. 5.
5. Install the screws for the Finger Baffles and the remaining screws
for the top edge of the Coupling Box Cover.
Install Sidewall Baffles
1. Avoid damaging the cell panel insulation by inserting the sidewall
baffle inward from the rear of coupling box to the indexing tab on
the primary cell panel then align the baffle with the coupling box
cover.
Insert the slot on the sidewall baffle over the tab on the primary cell
panel. See
Fig. 6.
NOTE: The front edge of the sidewall baffle has a slot that engages a tab
on the primary cell panel.
2. Insert the screws that attach the sidewall baffle to the primary cell
panel.
3. Align the rear edge of the baffle with the screw holes in the
coupling box cover.
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear
appropriate protective clothing and gloves when handling parts and
servicing furnaces.