Instruction Manual

Table Of Contents
REPLACEMENT ALUMINIZED PRIMARY HEAT EXCHANGER: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
3
4. Remove the back pressure switch tube that connects to the inducer
assembly.
5. Remove the wires from the back pressure switch. Note the location
of the wires for reassembly. (Non-modulating).
6. If the relief tube for the condensate trap is routed across the inducer
assembly, remove the tube from the port on the collector box and
from the stand-offs on the inducer and move the tube aside.
7. Set the pressure switches aside.
Inducer Assembly Removal
NOTE: See
Fig. 2 for inducer assembly detail and component locations.
1. Remove the door bracket from the front edge of the blower shelf.
2. Remove the wires that connect the main wiring harness to the
inducer motor harness.
3. Remove the condensate trap relief tube from the port on the
collector box and the stand-offs on the inducer housing.
4. Remove the screws from the tabs on inducer assembly that secures
the inducer to the collector box.
Note: there is one mounting tab directly under the vent elbow.
5. Remove the inducer assembly and set aside.
6. To avoid double gasketing and leakage, check to make sure the
drain gaskets for the inducer and the inducer inlet gasket are not
still attached to the inducer housing.
7. Remove any adhered gaskets from the front of the collector box.
Verify old gaskets are reusable or obtain new gaskets from the
distributor. Apply gaskets to the rear of the inducer housing and set
aside for reassembly later.
Condensate Drain and Trap Removal
NOTE: If the condensate trap is removed, a new gasket between the trap
and collector box is required. Obtain one from your local distributor. See
Fig. 1 and Fig. 7.
1. Disconnect external drain from condensate drain elbow or drain
extension pipe inside the furnace and set aside.
2. Disconnect the condensate trap relief hose from collector box port
and the molded retainer clips on the inducer housing.
NOTE: If condensate trap has a heat pad attached to the trap, trace the
wires for the pad back to the connection point and disconnect the wires
for the heat pad.
3. Remove the screw that secures the condensate trap to the collector
box, remove the trap and set aside.
4. Rinse condensate trap in warm water until trap is clean.
5. Clean relief port on Condensate Trap with a thin wire or paper clip,
rinse with warm water and set aside.
6. Flush condensate lines with warm water.
7. Shake trap dry.
Remove J-Box and Main Harness
1. Remove the screw that secures the J-Box cover to the J-Box
bracket. See
Fig. 3.
2. Disconnect the field wiring from the factory wiring and remove the
ground wire from the green ground screw on the J-Box bracket.
3. Remove factory wiring from the J-Box.
4. Disconnect the factory wires from the main limit switch.
5. Remove the screw that secures the door switch to the blower shelf
and the blower shelf door bracket. Remove the screws from the
blower shelf door bracket, and set the bracket aside.
6. Remove main harness from the slot in the blower shelf.
Collector Box Removal
1. Remove the screws that secure the collector box to the heat
exchanger cell panel and set aside. See
4
.
2. Remove collector box gasket and discard.
3. Flush out the collector box with warm water including the tube
ports. Clean tube ports on collector box with a thin wire or paper
clip, rinse with warm water and set aside.
A11299
Fig. 3 – J-Box Removal / Installation
A160109
Fig. 4 – Collector Box Removal / Installation
JBOX
MOUNTING
SCREWS
JBOX
MOUNTING
BRACKET
GROUND
SCREW
JBOX COVER
J-BOX
LOCATIONS