Tus neeg siv phau ntawv

Table Of Contents
AGATWNDTE01C: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
6
Representative drawing only, some models may vary.
A210137
NOTE: Horizontal Application
Do not connect return air to any side of the furnace
Do not stack condensing furnaces on top of each other
Horizontal stacking only permitted with mid-efficiency furnaces.
Back-to back installations, platform or suspended is approved for all
models
For back-to-back installations, Dimension “A” is measured across the
front of one furnace, similar to upflow/downflow installations.
Fig. 3 – Downflow/Horizontal Ductwork Connections
ELECTROSTATIC DISCHARGE (ESD)
PRECAUTION
1. Disconnect all power to the furnace. DO NOT TOUCH THE
CONTROL OR ANY WIRE CONNECTED TO THE CONTROL
PRIOR TO DISCHARGING YOUR BODY’S ELECTROSTATIC
CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the furnace
chassis which is close to the control. Tools held in a person’s hand
during grounding will be satisfactorily discharged.
3. After touching the chassis you may proceed to service the control or
connecting wires as long as you do nothing that recharges your
body with static electricity (for example; DO NOT move or shuffle
your feet, DO NOT touch ungrounded objects, etc).
4. If you touch ungrounded objects (recharge your body with static
electricity), firmly touch furnace again before touching control or
wires.
5. Use this procedure for installed and uninstalled (ungrounded)
furnaces.
6. Before removing a new control from its container, discharge your
body’s electrostatic charge to ground to protect the control from
damage. If the control is to be installed in a furnace, follow items 1
through 5 before bringing the control or yourself into contact with
the furnace. Put all used AND new controls into containers before
touching ungrounded objects.
7. An ESD service kit (available from commercial sources) may also
be used to prevent ESD damage.
SECTION 2
GENERAL - ALL ORIENTATIONS
Install furnaces
NOTE: Multipoise units can be installed in UPFLOW, DOWNFLOW,
or HORIZONTAL configurations.
Refer to furnace Installation, Start-Up, and Operating Instructions or
Product Specifications for appearance and dimensional drawing of
twinned furnaces and their connection locations.
NOTE: Follow all clearances for combustibles and service as shown in
the individual furnace installation instructions
1. Select two identical heating and airflow furnaces. (See Table 2 or
Table 3)
2. Remove bottom closure panels from both furnaces. (See
Fig. 5)
a. Remove main and blower access doors.
b. Remove screws from front filler panel.
c. Rotate front filler panel downward to remove.
d. Remove bottom closure panel and set aside.
e. Reinstall front filler panel and bottom closure panel (when used)
.
A10273
Fig. 4 – Removing Bottom Closure Panel for
Non-Condensing Furnaces
.
A170123
Fig. 5 – Removing Bottom Closure Panel for
Condensing Furnaces
3. Apply two factory-supplied foam strips to mating side of one
furnace. Locate strips equal distance from top and bottom as shown
in
Fig. 6.
4. Refer to the appropriate orientation to install the furnaces.
CAUTION
!
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit and component
damage.
Failure to follow this caution could result in unit and component
damage. Electrostatic discharge can affect electronic components. Take
Precautions during furnace installation and servicing to protect the
furnace electronic control. Precautions will prevent electrostatic
discharges from personnel and hand tools which are held during the
procedure. These precautions will help to avoid exposing the control to
electrostatic discharge by putting the furnace, the control and the person
at the same electrostatic potential.
Common
Supply Air
Plenum
Common Return Air
Plenum
Top View
Bottom
Closure Panel
Bottom Filler Panel
1. Lay furnace on the back or side
2. Remove the two (2) screws that secure the bottom
closure panel to the furnace casing and remove the
panel
SCREWS (2)
BOTTOM
CLOSURE
Representative drawing. Models may vary.