KGAPC0101ECM LOWER AMP KIT: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
3
A160070
Fig. 2 – Power Choke Mounted
Wire the Power Choke
1. Locate the 115 VAC black wire that runs from L1 on the control
board to the blower motor.
2. Disconnect the wire at the connector on the middle of the wire.
3. Connect each wire of the power choke to the appropriate mating
end of the black wire. See
Fig. 3.
4. Route wires away from sharp edges.
A160071
Fig. 3 – Power Choke Wiring
Apply New Max Unit Amps Label
1. Locate Unit Rating Plate on inside of the blower door.
2. Affix new label BELOW Unit Rating Plate.
3. Sign the label in the block provided on the label.
A160072
Fig. 4 – Rating Plate
A160117
Fig. 5 – Max Unit Amps Label Location
A160099
Fig. 6 – Max Unit Amps Label
Unit Checkout
1. Set thermostat to “OFF.”
2. Turn on power at external disconnect, fuse or circuit breaker.
3. Turn on gas at external shut-off or gas meter.
4. Check for gas leaks with a commercially available soap solution
made specifically for the detection of leaks to check all
connections.
5. Manually close blower door switch.
6. Initiate component test through circuit board by referring to
“Component Test” on status code label on blower access door for
complete test sequence information.
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death,
and/or property damage.
Never purge a gas line into a combustion chamber. Never test for gas
leaks with an open flame. Use a commercially available soap solution
made specifically for the detection of leaks to check all connections. A
fire or explosion may result causing property damage, personal injury
or loss of life.
AVERTISSEMENT
!
RISQUE D’EXPLOSION ET D’INCENDIE
Le non-respect des avertissements de sécurité pourrait d’entraîner des
blessures graves, la mort ou des dommages matériels.
Ne jamais utiliser une flamme nue por vérifier la présence des fuites de
gaz. Pour la vérification de tous les joints, utiliser plutôt une solution
savonneuse commerciale fabriquée spécifiquement pur la détection des
fuites de gaz. Un incendie ou une explosion peut entraîner des
dommages matériels, des blessures ou la mort.
342401-101 REV. A
Max Unit Amps 11.3
LOWER AMP KIT - KGAPC0101ECM
(POWER CHOKE HT08BB115)
WAS INSTALLED ON : _________________
DAY-MONTH-YEAR
BY:
(Name and address of organization making this installation),
which accepts the responsibility that this installation has
been properly made.
(Nom et adresse de l’organisation qui a
effectué l’installation) et qui accepte la
responsabilité que cette installation a
été effectuée correctement.
Amps Max 11.3
KIT DE BAS COURANT - KGAPC0101ECM
(ÉTRANGLEUR D’ALIMENTATION HT08BB115)
INSTALLÉ LE : _________________POUR
JOUR-MOIS-ANNEE
PAR: