Datasheet
©2015 Beha-Amprobe
®
13104-engBeha-Amprobe
®
| In den Engematten 14 | 79286 Glottertal, Germany | Tel: +49 (0) 7684 8009-0 | info@beha-amprobe.de | www.Beha-Amprobe.com
2100 Series Specifications
2100-Alpha 2100-Beta 2100-Gamma
Voltage Test
LED voltage range
12... 690 V AC/DC 12... 690 V AC/DC 12... ≥690 V AC/DC
LED indicator
±12, ±24, 50, 120, 230, 400, 690 V ±12, 24, 50, 120, 230, 400, ≥690 V
LED tolerances
acc. to EN 61243-3:2010
LCD voltage range
12... 690 V AC/DC 6...1000 V AC / 6...1200 V DC
LCD resolution
1 V
LCD tolerance
± (3% rdg + 3 LSD)
Frequency range
DC, 16 2/3 Hz…400 Hz
LED and LCD response time
<1s
Acoustic indication
≥50 V AC, ≥120 V DC
Voltage detection
Automatic (AC/DC)
Polarity detection
Full range
Range detection
Automatic
Current I
(load buttons not activated)
≤3.5 mA AC/DC at 690 V AC/DC
≤3.5 mAAC at 1000 VAC /
≤4.5 mADC at 1200 VDC
Internal load
(load buttons not activated)
Approximately 2.4 W at 690 V AC/DC
Approximately 3.5 W at 1000 VAC /
Approximately 5.4 W at 1200 VDC
Test current switchable load
(load buttons activated)
≤350 mA AC/DC at 690 V AC/DC
≤300 mAAC at 1000 VAC /
≤350 mADC at 1200 VDC
Switchable load
(load buttons activated)
Approximately 240 W at 690 V AC/DC
Approximately 300 W at 1000 VAC /
Approximately 420 W at 1200 VDC
Automatic power ON
LED: >12 V (activated load buttons)
>24 V (w/o load buttons)
LED: >12 V (activated load buttons)
>24 V (w/o load buttons)
LCD: >12V
LED: >12 V
LCD: > 6V
Trip Test of RCD (earth leakage circuit breaker)
Test current switchable load
(load buttons activated)
>30 mAAC at 230 VAC
Single Pole Phase Test
Voltage range
180…690 VAC against earth 100…1000 VAC against earth
Frequency range
40 Hz…70 Hz
Acoustic indication
yes
Indication
Red LED
Continuity Test (Rx) / Diode Test
Range
0….500 kΩ
Tolerance
0% to +50%
Test current
<5 μA
Acoustic indication
yes
Diode test
yes
Indication
Red LED
Overvoltage protection
690 V AC/DC 1000 VAC/1200 VDC
Automatic power ON
< 500 kΩ
Phase Rotation Indication
Voltage range
340…440 V AC phase to phase
170…1000 V AC phase to phase
Frequency range
47…63 Hz 40…70 Hz
Indication
Red LED
Resistance Measurement (Ω ) / Low Resistance Indication “r“ (2100-Gamma only)
Resistance range on LCD
0…1999 Ω
Resolution
1 Ω
Tolerance
± (5% rdg + 10 LSD) at 20°C
Temperature coefficient
± (5 LSD / 10 K)
Test current
<30 μA
Low resistance indication
Acoustic indication <10…50 Ω
Overvoltage protection
690 V AC/DC 1000 VAC/1200 VDC
Non-Contact Voltage Indication/Electric Field (NCV/EF)
Voltage range
– 100…1000 VAC
Frequency range
– 50…60 Hz
Indication
–
3 levels shown by LCD segments:
Data Hold
Data hold
– only voltage measurement (12...690V AC/DC) voltage and resistance measurement, NCV
Measurement Area Illumination / Torch Light
Torch light
White LED
General Specifications
Operation time (DT)
30 s
Recovery time
240 s
Operating temperature
-15°C to +55°C
Storage temperature
-15°C to +55°C
Humidity
Max. 95% RH
Operating altitude
Up to 2000 m
Safety rating (overvoltage category) CAT IV / 600V, CAT III / 690V CAT IV / 600V, CAT III / 1000V
Pollution degree
2
Protection degree
IP 64
Safety regulations
IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011
Approvals, compliance
GS mark from TÜV Rheinland, CE
Power Supply
Battery 2 x 1.5V (AAA/ IEC LR03)
Power consumption
Approximately 60 mA
Battery lifetime
More than 10000 measurements (<5 s / per measurement)
Dimensions (HxWxD)
Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)
Weight
Approximately 320 g (0.71 lb)