User Manual

4
HOW TO TEST
For operation please refer to instruction manual of the relevant test equipment to be used.
MAINTENANCE
When using the test accessory in compliance with the user manual, no special maintenance is required. However,
should functional errors occur during normal operation, the after sales service will repair your accessory. Please
contact the local service office.
CLEANING
If the accessory needs to be cleaned after daily usage, use a wet cloth and a mild household detergent.
Prior to cleaning, disconnect the test cable from all measurement circuits.
Never use acid-based detergents or dissolvent liquids for cleaning.
After cleaning, do not use the accessory until it is dried completely.
SPECIFICATIONS
Type EVC-13 Test Cable EVC-20 Test Cable
Description
AC charging mode 3, suitable to
IEC 62196-2 type 1 or SAE J1772
with vehicle connector
(type 1, 5P single-phase)
AC charging mode 3, suitable to
IEC 62196-2 type 2 socket outlet or
fixed cable with vehicle connector
(type 2, 7P three-phase)
Input voltage
Up to 250 V (single phase system) /
up to 430 V (three phase system), 50/60 Hz, max 10 A
Length 590 mm (including both connectors)
Weight Approx. 550 g
CE directive Low Voltage Directive LVD 2014/35/EU
Safety
IEC/EN 61010-1:2010
IEC/EN 61010-2-031:2015
EMC Not applicable
Working temperature range 0 ... +40 °C
Storage temperature range -10 ... +50 °C
Reference humidity range 10 ... 60% relative humidity w/o condensation
Working humidity range 10 ... 85% relative humidity w/o condensation
Pollution degree 2
Measurement category CAT II 300 V
Altitude above sea level 2000 m max.