Datasheet

Beha-Amprobe
®
Division of Fluke Corp. (USA)
c/o Fluke Europe BV
In den Engematten 14
79286 Glottertal, Germany
Tel. +49 (0) 7684 - 8009-0
info@beha-amprobe.de
beha-amprobe.de
52 Hurricane Way
NR6 6 JB United Kingdom
e-mail: info@beha-amprobe.co.uk
beha-amprobe.com
Science Park Eindhoven
5110 NL-5692 EC Son
The Netherlands
Tel. +31 (0) 40 267 51 00
beha-amprobe.com
©2019 Beha-Amprobe
®
6011266 A-eng
Correlation between vehicle state and CP-signal
Main Applications
Safety testing of charging stations
Functional testing of charging stations
Trouble shooting / repair of charging stations
Vehicle State Description PWM voltage at CP terminal
A
Electric vehicle (EV) not connected ± 12 V 1 kHz
B
Electric vehicle (EV) connected, not ready to charge + 9 V / -12 V 1 kHz
C
Electric vehicle (EV) connected, ventilation not required, ready to charge + 6 V / -12 V 1 kHz
D
Electric vehicle (EV) connected, ventilation required, ready to charge + 3 V / -12 V 1 kHz
Specifications
Functions
PE Pre-Test
Yes, with touch electrode
PP simulation
open, 13 A, 20 A, 32 A, 63 A
CP states
A, B, C, D
CP Error “E”
on/off
PE Error (Earth fault) on/off
Outputs (for test purpose only)
Measuring terminal L1, L2, L3, N and PE Max. 250/430 V, CAT II 300 V, max. 10 A
Mains socket Max. 250 V, CAT II 300 V, allowed current max. 10 A
CP Signal output terminals PWM communication protocol, approx. max. ±12 V
General Features
Input voltage Up to 250 V (single phase system) / up to 430 V (three phase system), 50/60 Hz, max 10 A
EV Connector (EVC-20) AC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or xed cable with vehicle connector (type 2, 7P three-phase)
EV Connector (EVC-13) OPTIONAL AC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with vehicle connector (type 1, 5P single-phase)
Mains outlet protection Fuse T 10 A/250 V, 5×20 mm
Dimensions (W × H × L) 110 × 45 × 220 mm (length without connection cable and connector)
Weight Approx. 1 kg (Adapter EVA-500-x + EC-connector EVC-20)
IP protection class IP54
CE directive Low Voltage Directive LVD 2014/35/EU
Safety
IEC/EN 61010-1:2010
IEC/EN 61010-2-030:2010
EMC Not applicable
Working temperature range 0 ... +40 °C
Storage temperature range -10 ... +50 °C
Reference humidity range 10 ... 60 % relative humidity w/o condensation
Working humidity range 10 ... 85 % relative humidity w/o condensation
Pollution degree 2
Protection class II
Measurement category CAT II 300 V
Altitude above sea level 2000 m max.