Electrical Specification Accuracy (23 °C ± 5 °C & < 75% R.H.), cont.
ACD-10 PLUS 600A Clamp-On Multimeter
Function Range Accuracy
AC Current (Clamp-on 50Hz / 60Hz)
Range Accuracy
1) 2) 3)
40.00, 400.0, 600 A ±( 1.5% + 8 digits)
Overload Protections: ACA Clamp-on jaws : 600 A rms continuous
ACD-10 Plus: Average Sensing
1)
Max Induced error from adjacent current carrying conductor: 0.05 A
2)
Specified accuracy is from 1% to 100% of range and for measurements made at the jaw center. When the conductor is not positioned
at the jaw center, position errors introduced are: Add 2% to specified accuracy for measurements made BEYOND jaw marking lines
(toward jaw opening)
3)
Add 8 digits to specified accuracy @ reading < 10% of range
Resistance
400.0 W ±( 0.8% + 8 digits)
4.000, 40.00, 400.0 kW ±( 0.6% + 4 digits)
4.000 MW ±( 1.0% + 4 digits)
40.00 MW ±( 2.0% + 4 digits)
Open Circuit Voltage : 0.4 VDC typical
Transient protection : 6.5 kV (1.2/50μs surge)
Frequency
Function Sensitivity (Sine RMS) Range Accuracy
400.0 mVac 350mV 1 0 Hz ~ 2 kHz ±( 0.5%+4 digits)
4.000 Vac 1V 5 Hz ~ 5 kHz ±( 0.5%+4 digits)
4.000, 40.00 Vac 32V 5 Hz ~ 100 kHz ±( 0.5%+4 digits)
400.0 Vac 90V 5 Hz ~ 10 kHz ±( 0.5%+4 digits)
600 Vac 500V 5 Hz ~ 5 kHz ±( 0.5%+4 digits)
400.0 Aac 60A 40 Hz ~ 400 Hz ±( 0.5%+4 digits)
Display counts: 5000
Resolution: 0.001Hz
Overload Protection : ACA Clamp-on jaws : AC 600A rms continuous
Transient protection : VAC input jacks : 6.5kV (1.2/50μs surge)
Capacitance
Range
1)
Accuracy
2) 3)
500.0nF, 5.000μF, ±( 3.5% + 6 digits)
50.00μF, 500.0μF, 3000μF
1) Additional 50.00nF range accuracy is not specified
2) Accuracies with film capacitor or better
3) Specified with battery voltage above 2.8V (approximately half full battery).
Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V
Transient protection: 6.5 kV (1.2/50 μs surge)
Audible Continuity Tester
Audible indication: between 10 W and 120 W.
Transient protection: 6.5 kV (1.2/50 μs surge)
Diode Tester / Open Circuit Voltage Test Current
(Typical) < 1.6 VDC @ 0.25 mA
Transient protection: 6.5 kV (1.2/50 μs surge)
Max Hold* (where applicable)
Specified accuracy ± 50 digits for changes > 25 ms in duration