7.0 Technical Data
(at 23° C ± 5° C, max. 75 % rel. humidity). Temperature coefficient (<18°C or >28°C):
0.15 (Specified Accuracy) /°C
Display: 4digit, LCD incl. functions and symbols
Range Selection: automatic
Auto-Power-Off: approx. 30 min.
Overload display: OL
Measuring rate: 2 measurements/sec. (LCD)
Clamp opening: ca. 30 mm (1.2 inch)
Overvoltage Categorie: CAT II, 600 V / CAT III, 300 V
Pollution degree: 2
Height above MSL.: up to 2000 m
Battery display: at low battery
Power supply: Batterie 2 x 1,5 V IEC LR6 (alkaline)
Current Consumption: approx. 10 mA
Operation temperature: -10° C … 50° C at less than 85% rel. H.
Storage temperature: -20° C … 60° C at less than 75% rel. H.
Dimension: 210 x 62 x 35,6 mm
Weight: approx. 200 g
Voltage AC TRMS
Crest Faktor <4, Input Impedance 10MΩ, max. Peak Voltage 850 Vss
Range Resolution Accuracy
5 V...600 V 0,1 V ± 0,5 % ± 5 D (50/60Hz)
20 V...600 V 0,1 V ± 1,5 % ± 5 D (45-1kHz)
Overvoltageprotection: 800V AC
Current AC TRMS (mA and A)
Crest Faktor <4, max. Peak Voltage 850 mAss (mA Range) or
70 Ass (A Range)
Range Resolution Accuracy (50/60Hz)
0,50...60,00 mA 0,01 mA ± 0,5 % rdg. +5 D
60,00...99,99 mA 0,01 mA ± 0,5 % rdg. +50 D
100...600,0 mA 0,1 mA ± 0,5 % rdg. +5 D
0,050...3,000 A 0,001 A ± 0,5 % rdg. +5 D
3,000...9,99 A 0,001 A ± 0,5 % rdg. +50 D
10,00...30,00 A 0,01 A ± 0,5 % rdg. +5 D
30,00...50,00 A 0 0,01 A ± 1,0 % rdg. +5 D
14