Installation manual
Unit Installation  Antenna Unit 
Apr 2004   11 
3
The transceiver unit and the antenna unit are connected by 
a single 50 Ω double screen coaxial cable. The maximum 
length of the coaxial cable depends on the type of cable 
used. 
The table below shows the specifications for Thrane & 
Thrane A/S standard cables.   
Cable Type  Max. 
Length 
RG223 10 m 
RG214  30 m 
SA07272 50 m 
SA12272  70 m 
The coaxial cable can be extended if it complies with the 
specified losses incl. connection listed below. 
•  Maximum RF loss, 1525 – 1660 MHz:  10 dB 
•  Maximum DC loss, R
loop
:      0.5 Ω 
Where exposed to mechanical wear - on deck, through 
bulkheads, etc. - steel pipes should protect the cables. 
Standard procedures should otherwise be followed for 
cabling in ship installations. 
3.3.2  Antenna Unit Mast Design 
The antenna mast must be designed to carry the 4.5 kg 
weight of the antenna unit. It must also be able to 
withstand wind forces up to 140 knots on the radome as 
well as onboard vibrations. 