User Manual

14
NATURAL GAS CONVERSION
NATURAL GAS CONVERSION
3. Attach clip on aeration shutter to each burner as shown:
4. Refit burners ensuring the injector is located inside the
burner inlet.
5. Remove LPG hose and regulator assembly and replace
with natural gas hose and regulator assembly
6. Replace the ULPG gas type label with the natural gas
label supplied.
7. Leak test using same procedure for ULPG, as detailed
on page 12 (leak test points shown below).
8. Attach restraining tether (supplied with natural gas
conversion kit) to anchor point on barbecue, and fasten
within 50mm of fixed gas outlet with suitable fastener.
Ensure the length of the tether does not exceed 80% of
the length of the hose to the fixed gas supply outlet.
Universal
LPG
GAS AUTHORITY FOR CONFIRMATION OF GAS
REFER TO LOCAL
TYPE IF DOUBT
Aeration shutter
anchor point
leak test point
leak test point
restraining tether
check hose for signs
of abrasions, cracks
or leaks
replace ULPG with
Natural Gas label