User Manual

13
GAS BOTTLE SAFETY AND LEAK TESTING
NATURAL GAS CONVERSION
NATURAL GAS CONVERSION
Natural gas installation
NOTE: Conversion of this unit to natural gas must be carried
out by a qualified licensed person and a Certificate of
Compliance must be issued to the owner on completion of
the installation and conversion.
Converting the unit to natural gas
This barbecue is supplied set up for Universal LPG and is
labelled accordingly. A natural gas conversion kit is available
as an accessory by contacting Electrolux Customer Service
Centre. Refer to Accessories section on page 19.
The components required for conversion
1 x Natural gas hose and regulator assembly
1 x Small bag containing:
2 x 1.83mm brass injectors
2 x Clips, aeration shutter
1 x Natural gas sticker
Procedure
1. Remove 4 screws fastening the stainless steel burners
to allow access to brass injectors.
2. Unscrew ULPG 1.10mm injectors and replace with NG
injectors 1.83mm.
Burner
Screw
Brass injectors