Specifications

Beech Ovens Page 55 28/07/2011 (C)
RND-REC-RGO Manual (R1) Confidential and Proprietary
Display burner shroud
Tube burner shroud
The stainless steel burner shroud should now be fitted inside the oven. The main
purpose of the shroud is to protect the burner from debris and foreign objects. Ensure
that these are fitted properly, as failure to do so may result in burner and/or ignition
problems.
Mount the 6mm-diameter Thermocouple probe into the pre-fitted brass gland nut in the
oven base. The tip of the Thermocouple should be flush or 0-3mm below the oven
cooking surface.
(The hole in the gland nut is drilled eccentric to allow for any misalignment that may
occur between the gland nut and the base brick during transport. Should the
Thermocouple not align with the hole in the base brick, turn the gland nut slowly until it
aligns correctly as per the diagram below.)
A close-up view of the
Thermocouple shows the gland nut
mounted into the underside of the
oven base.
NOTE: Tighten firmly, though do
not over tighten the clamp fitting.